Справочная информация и описание кабеля
ESDI
The ESDI interface requires two cables, one for control and
one for data. The control cable is shared between the two drives.
But each drive has each own data cable. By twisting some wires on
the control cable it won’t be necessary to set the ID for each
drive, since the twist will do the job. Wires 25 to 29 should be
twisted between drive 1 & drive 2.
Controller           Drive 2   Twist   Drive 1
+—+                   +—+            +—+
|::|===================|  |============|  |  <-Pin 1
|::|===================|  |============|  |
|::|===================|  |============|  |
|::|===================|  |============|  |
|::|===================|  |=====/=====|  |
|::|===================|  |=====/=====|  |
|::|===================|  |============|  |
+—+                   +—+            +—+
Control cable
 (to the Controller)
 (to the Controller)
 (to the Drive 2)
 (to the Drive 2)
 (to the Drive 1)
 (to the Drive 1)
34 PIN IDC FEMALE to the Controller.
34 PIN IDC FEMALE to the Drive 2.
34 PIN IDC FEMALE to the Drive 1.
    Controller
Drive 1
Drive 2
    Wire 1-24
1-9
1-9
1-9
    Wire 25
25
29
25
    Wire 26
26
28
26
    Wire 27
27
27
27
    Wire 28
28
26
28
    Wire 29
29
25
29
    Wire 30-34
30-34
30-34
30-34
Data cable
 (to the Controller)
 (to the Controller)
 (to the Drive)
 (to the Drive)
20 PIN IDC FEMALE to the Controller.
20 PIN IDC FEMALE to the Drive.
    Controller
Drive
    Wire 1-20
1-20
1-20
    Contributor:
Joakim Цgren
    Source:
TheRef TechTalk
  Copyright © The Hardware Book Team 1996-2004.
May be copied and redistributed, partially or in whole, as appropriate.
Document last modified: 2002-01-10